A plate held between a matched pair of orifice flanges with the pressure tappings drilled radially through the flanges. The most widely specified way to mount an orifice plate, and the reference case in ISO 5167-2. Supplied as a complete union — plate, both flanges, studs, nuts, jack screws and gaskets — so nothing has to be sourced separately on site.

Size rangeNPS 2″ – 24″
Pressure classClass 150 – 2500
TappingsFlange, per ISO 5167-2 or AGA-3
Flange standardASME B16.5 / B16.36
Request a quote PDF Download datasheet
Range

Four build levels, one union

The difference between them is how much of the impulse line arrives already built. Each level adds parts that would otherwise be assembled in the field, where the tapping symmetry and the slope of the impulse legs are hardest to control.

Orifice flange union, standard

Standard Union

Plate · flanges · fasteners

Plate with tab handle, matched flange pair, flange tappings, studs and nuts, jack screws and gaskets. Tappings plugged or prepared for the customer's impulse piping.

Orifice flange union with weld-on root valves; tappings horizontal

With Weld-On Shut-Off Valves

Root valves fitted

Welded pressure take-off nipples with one upstream and one downstream root valve, isolating the impulse lines without breaking into the flange tapping.

Orifice flange union with two horizontal condensate pots, the root valves below them

With Valves and Condensate Pots

Steam and condensing service

Two symmetrically positioned condensing chambers ahead of the root valves, keeping the impulse legs full and equal on steam and other condensing media.

Orifice flange weldment

Orifice Flange Weldment

Supplied as one spool

The union welded into pipe sections and supplied as a single spool with flanged process ends. Arrives ready to drop into the line with no site welding at the tapping.

Specification

Technical data

Size range NPS 2″ – 24″ (DN 50 – DN 600), larger on request; below NPS 2″, a small bore meter run is supplied instead
Pressure class ASME Class 150 – 600 standard; up to Class 2500 special production (Class 2500 up to NPS 12″); EN 1092-1 PN 6 – PN 400
Flange standard In most projects machined from ASME B16.5 flanges to the project's tapping detail; ASME B16.36 orifice flanges (Class 300 – 2500) where the standard detail suits the duty; EN 1092-1 on request
Facing Raised face or ring type joint; flat face on request. On ASME B16.36 flanges, ring type joint from Class 600
Tapping size ½″ NPT standard; ¼″ and ¾″ available
Plate thickness Per ISO 5167-2 against line size and differential pressure; AGA-3 where D < 50 mm
Bore designs Concentric, eccentric, segmental, quadrant, conical entrance, multi-hole (conditioning)
Measuring uncertainty Stated on the calculation sheet for the duty; discharge coefficient uncertainty to ISO 5167-2: 0.50 % at β 0.50, 0.75 % at β 0.75
Permanent pressure loss About 95 % of the differential at β 0.20, 73 % at β 0.50 and 45 % at β 0.75, falling as β rises (ISO 5167-2, 5.4.1)
Sealing surface ASME B16.5 RF and RTJ facings, or EN 1092-1 facings to order
Marking Plate: INLET, tag, serial and job numbers, bore, beta, material and heat number, marked on the upstream face (on the handle of paddle-type plates); rating and flow direction on the flange
Quality control ISO 9001 system; PED where it applies; hydrostatic test, or pneumatic where the project specifies, on the orifice flange weldment; EN 10204 3.1 certificates, 3.2 on request
Documentation Sizing calculation, material certificate (EN 10204 3.1), dimensional report
Materials

Material selection

The plate is chosen for the medium, the flanges for the piping class. Temperature decides which end of the carbon and alloy range applies.

Orifice plate316 / 316L, 304 / 304L stainless steelStandard across gas, steam and liquid service. Duplex (UNS S31803 / S32205), Alloy 400 (UNS N04400), Alloy 625 (UNS N06625) and Alloy C-276 (UNS N10276) where the medium is aggressive.
Orifice flangesA105N carbon as standard; A350 LF2 for low temperature; A182 F11 / F22 alloy or F316 stainless to the piping classTaken from the piping class so the union is a like-for-like part of the run.
Temperature-driven selectionLF2 down to −46 °C for gas service; F22 and F91 for steam and hot processThe two ends of the range never mix. Low temperature grades go where the minimum design temperature calls for them; power and refining steam lines take the creep resistant ones.
Gaskets & boltingPTFE, graphite and spiral wound gaskets; A193 B7 / B16 studs, A320 L7 for low temperatureSelected with the flange rating and the service temperature, so the joint and the flange are qualified to the same limit.

Where it runs

Sectors this family is specified into most often.

Thermal power Natural gas Refining Petrochemical Steam & utilities Water & wastewater
Dimensions

Dimension drawing

Flange outside diameter, bolt circle, bolt hole count and raised face diameter follow ASME B16.5, or ASME B16.36 where its standard tapping detail is used, for the class you specify. The plate thickness follows ISO 5167-2, or AGA-3 where D < 50 mm; the tappings follow ISO 5167-2 where the tap hole stays below 0.13D and 13 mm (5.2.2.7), otherwise AGA-3. Both are confirmed on the dimensional report shipped with the union.

ØDoFlange outside diameter
ØDkBolt circle diameter
ØDrRaised face diameter
n × ØdbNumber and diameter of bolt holes
DPipe inside diameter
p1, p2Flange tappings, drilled radially through each flange
Full drawing set →
Dimension drawing of an orifice flange union: flange face with outside diameter, bolt circle, raised face and bolt holes; section with the plate between the two flanges, gaskets, studs, flange tappings and a jack screw

Documents

PDF Orifice flange union datasheet EN · 5 pages → PDF White paper 01 — The Silent Drift EN · 5 pages → XLS Sizing enquiry sheet Fill in and send back →
Specification text For tender documents and instrument data sheets. Fill in the values in brackets; the text names no manufacturer.
  1. Primary element: orifice plate between a pair of orifice flanges with flange tappings; line size [NPS …], rating [ASME Class … / PN …].
  2. Flanges: [ASME B16.5 flanges machined to the tapping detail / ASME B16.36 orifice flanges / EN 1092-1], [RF / RTJ] facing.
  3. Tappings: [½″ NPT / ¼″ NPT / ¾″ NPT], drilled radially through each flange; to ISO 5167-2 where the tap hole stays below 0.13D and 13 mm, otherwise AGA-3.
  4. Plate: [concentric] bore; thickness to ISO 5167-2 against line size and differential pressure, AGA-3 where D < 50 mm; material [316L] stainless steel. Flanges to the line piping class [ … ].
  5. Marking: plate INLET, tag, serial number, bore, β, material and heat number on the upstream face (on the handle of paddle-type plates); rating and flow direction on the flange.
  6. Testing and documents: hydrostatic test of the orifice flange weldment (pneumatic where specified); sizing calculation, material certificate EN 10204 3.1 (3.2 where stated), dimensional report.

Related products

All orifice plate flow elements →
Paddle-type orifice plate with plain handle

Single Orifice Plate

The plate that sits in the union

Single Chamber Fitting

Single Chamber Fitting

Plate access without full line entry

Dual Chamber Fitting

Dual Chamber Fitting

Plate change under pressure

Condensate Chamber

Condensate Chamber

Seal pots for steam service

Request a quote

Orifice Flange Union

Send the line size, class, facing and the medium. We come back with a sized plate, the union bill of material and a price — usually within two working days.

Prefer email? info@inkotekenerji.com
A P&ID, datasheet or specification, or for a replacement a nameplate photo — up to 5 files, 10 MB in total: PDF, Excel, Word, DWG, DXF, JPG or PNG. Larger files to info@inkotekenerji.com, quoting the reference we send you.